Product Details:
Payment & Shipping Terms:
|
Handle: | 3 | Application: | Hair Removal, Wrinkle Removal,skin Rejuvenation, Pigmentation, Acne, Vascular |
---|---|---|---|
IPL Power: | 3500W | Wavelength: | SHR 650nm-950nm; Elight 430/530/640-1200nm Standard; IPL 530~1200nm480/560/590/690/750-1200nm Optional |
Energy Density (Fluence): | 1-26J/cm²(SHR), 1-60J/cm²(Elight) | Spot Size: | 15×50mm²(SHR), 15×35mm²(Elight), 10x40mm2 (IPL) (12×33mm², 10×40mm² Optional) |
Net Weight: | 60KG | Dimensions (W X L X H): | 63×53×126cm |
Application: | For Commercial | Application: | For Commercial |
After-sales Service Provided: | Online Support, Video Technical Support | After-sales Service Provided: | Online Support, Video Technical Support |
Warranty: | 2 Years | Warranty: | 2 Years |
Brand: | KES | Brand: | KES |
Quantity: | 1 | Lead Time: | 15 |
Lead Time: | 15 | Lead Time: | 15 |
Highlight: | ipl hair removal equipment,hair removal machine |
Intelligent Elight IPL RF Removing Hair Machine Wrinkle Acne Pigmentation Removal Equipment
Working Principle:
MED-140c+ comes standard with 3 handles, you can choose IPL/SHR/RF/E-light according to your needs.
Similar to lasers, the basic principle of IPL devices is a more or less selective thermal damage of the target. The combination of prescribed wavelengths, fluences, pulse durations, and pulse intervals facilitates the treatment of a wide spectrum of skin conditions.
SHR=Super Hair Removal,it’s a revolutionary technology of hair removal which is having a sweeping success. (adopt technology AFT,EDF)
SHR combines laser technology and the benefits of the pulsating light method achieving practically painless results.
SHR combined with “In Motion” represents a breakthrough in permanent hair removal with light technology. The treatment is more pleasant than with the conventional systems and your skin is better protected.
Comparison:
Parameter | Normal IPL | MED-140C+ | Advantages |
Pulse |
Multi pulse mode 1-6/1-15pulses |
Single pulse | Single pulse mode can emit energy averagely, but multi-pulse mode focus energy on first pulse, very easy to burn skin |
Wavelength | HR: 640-1200nm | SHR 650nm-950nm; Elight 430/530/640-1200nm standard; IPL 530~1200nm480/560/590/690/750-1200nm optional | Moving IPL filtered violet light and infrared light, which will eradiate and absorb water from target skin. So moving IPL does not have any side-effect to body. |
DEC Technology | Unavailable | Available | Make sure energy output accurate and same with the display all the time, which makes operation easy and safe. |
Particle filter & De-ionizer filter |
Unavailable | Available | Prolong lifespan of handpiece and machine! |
Frequency | 0.2-1Hz | 1-10Hz | Speed up the treatment, save time |
Work technology | Stationary technology | Stationary technology & In-motion technology | Moving IPL can use less time to do treatment on back, leg and arm. |
Power supply | 1200W | 3500W | Make fast charging and achieve fast shooting |
Timer | no | 1-30s | Accurate control the time and convenient for operator |
Spot size | 10*40mm | 15×50mm²(SHR), 15×35mm²(Elight), 10x40mm2 (IPL) (12×33mm², 10×40mm² optional) | Biger size increase the efficiency |
Operation Interface | 7.4” interface | 10.4” intelligent interface | More easy for operator |
Application:
Before&After:
Advantages:
Difference Of IPL SHR & Traditional IPL or laser:
Traditional laser or IPL technologies employ short impulses of approximately 2-300 milliseconds, applying a vast amount of energy (12-120 J/cm2). Energy is transported to the hair root through melanin, where warmth of 65-72° Celsius is produced. Energy reaches the root of the hair follicle solely through melanin. Skin and red blood cells have a similar absorption coefficient as melanin and therefore also absorb the high levels of energy produced by the laser and IPL methods.
SHR technology, on the other hand, utilizes the melanin path only partially (50%)., and combining In-Motion technology, gently warms the skin helping penetrate down to the follicles which produce hair growth.
Research has shown that a slower, but longer heating process is considerably more effective for permanent hair removal than high and short levels of energy. Therefore, when using SHR, the device is passed over the tissue multiple times (in motion) using low energy but a high rate of repetition (up to 10Hz, i.e. 10 times per second) instead of using the traditional method with single, high-energy impulses. Thus, the hair melanin, as well as the tissue of the stem cells, is heated with low energy at a slow pace and over a longer period of time to a comfortable temperature of 45° Celsius.
Technical Specifications:
Wavelength (Spectrum) |
650-950nm(HR) 510-1200nm(SR) , 430/530/640-1200nm (15*35mm) |
Energy Density (Fluence) |
1-26J/cm2(SHR) 1-60J/cm2(Normal) |
Spot Size |
15x50mm2 (HR); 10x40mm2 (SR); 15*35mm2 (interchangeable) |
Pulse duration | 1-15ms |
Pulse | Single |
Pulse Repetition Rate | 1-10Hz |
Timer | 1-30s |
IPL Peak Power | 2500W |
Cooling | Continuous Crystal contact cooling (-4°C-2°C ) + Air cooling + Closed water circulation cooling |
Stand-by Working | Continuously for 18 hours |
Display | 10.4" True Color LCD Touch Screen |
Electrical Requirements | 100-240VAC, 20A max., 50/60Hz |
Net Weight | 60 kgs |
Dimensions (WxDxH) | 63*53*126cm |
Contact Person: Miss. Jackie